Overview
As much as half of the energy used in your home goes to heating and cooling. So making smart decisions about a home’s HVAC system can have a big effect on utility bills — and comfort.  Systems 9RLS2, 12RLS2 and 15RLS2 are among the most efficient mini-splits in North America, with Seasonal Energy Efficiency Ratings of up to 27.2-SEER.  

The RLS2 systems are packed with features specifically created to save you money – like Energy Saving Program, or ESP, a programmable remote control and inverter technology.
  Features
 

Energy Saving Program (ESP)
ESP LogoHalcyon system knows how to save you money even when you forget. If you leave the room without turning the unit off, ESP knows that you left and 20 minutes later, set temperature is increased by 
4°F when cooling and reduced by 8°F when heating. When you come back to the room, it returns to previous operating mode. This prevents wasteful operation to save energy without you having to think about it.
 
ESP

 

Programmable Remote
Weekly timer can be easily set by wireless remote controller. ON, OFF can be set up to 4 times in one day and up to 28 times in one week. For other modes, program timer and sleep timer can also be selected by pushing a single button.

 
Powerful Heating Down to -15°F Outdoor Temperatures
 Heating capacity at low outdoor temperatures was improved by adopting a large heat exchanger and a high capacity compressor. Rated heating capacity is maintained up to 20°F. This new model can operate down to -15°F.
World Class  P erformance



 Proper sizing and installation of equipment is critical to achieve optimal performance.  Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria.  Ask your contractor for details or visit www.energystar.gov.  Since mini splits have little to no ducting, they forego those energy losses typically associated central forced-air systems. Duct losses can easily account for more than 30% of energy consumption, especially if the ducts are not sealed tight or in an unconditioned space such as an attic or crawlspace. With ratings as high as 27.2-SEER (Seasonal Energy Efficiency Ratio), systems 9RLS2, 12RLS2 and 15RLS2 are among the highest rated efficiency equipment available anywhere! 
Proper sizing and installation of equipment is critical to achieve optimal performance.  Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria.  Ask your contractor for details or visit www.energystar.gov.
Base Freeze Prevention
RLS2H outdoor models are equipped with a base heater that prevents condensate from freezing.  The cultivated base design discharges melted water through many holes.  Without a heater, freezing condensate can cause noise, damage to fan blade, condenser, and system performance.
Quiet Operation
Ductless heat pumps and air conditioners are comprised of an indoor and outdoor unit, allowing for a peaceful inside environment by enabling components like compressors and motors outdoors to be installed outside.
Inverter Technology
Through  advanced technology, Inverter air conditioners are more economical to operate and quieter to run than conventional units. They can handle greater extremes in temperature, are smoother and more stable in operation, and reach the desired temperature more quickly than conventional air conditioners.
 
The Inverter component allows the outdoor unit to vary its speed and output to match the required capacity of the indoor unit. Thus, the Inverter model can achieve 30% more operating efficiency than conventional models and therefore, is much less expensive to run.   
Other Standard Features Include:
Wireless Remote Control
Sleep Timer
Weekly Timer
Dry Mode
Auto Louver: Up/Down
Auto Mode
Quiet Mode (Indoor)
Economy Mode
Low Noise Mode (Outdoor) 
Program Timer
Auto Restart/Reset
Auto Changeover*
Low Ambient Heating
Apple Catechin Filter
Ion Deodorizing Filter
Minimum Heat (50°F/10°C)
Powerful Operation Mode
 

 

Specifications
Model
15RLS2H
Year
2017
Sale Type
New
Manufacturer
Fujitsu
Cooling BTU/h
12,000
Outdoor Design Temp Fº DB/WB
47/43
Heating BTU/h
18,000
SEER
21.5
EER Clg/Htg
12.0/13.3
HSPF
10.3
Power Supply (V)
208-230
Noise Level Db (A) Cooling Hi
45
Noise Level Db (A) Cooling Med
40
Noise Level Db (A) Coolin Lo
33
Noise Level Db (A) Cooling Quiet
25
Noise Level Db (A) Heating Hi
45
Noise Level Db (A) Heating Med
40
Noise Level Db (A) Heating Lo
34
Noise Level Db (A) Heating Quiet
27
INDOOR Weight (lbs)
21
OUTDOOR Max Fuse Size (A)
20
OUTDOOR Weight (lbs)
88
REFRIGERANT PIPING Length (ft)
66
Discharge Vapor Line (OD) Inches
1/4
Suction (OD) Inches
1/2